Skip to content

UISetCSADTargetValue ​

Status UnverifiedOpcode253TypeWrite

Sets a Sense and Dispense module's pH set point, 7.0 to 8.0 in steps of 0.1.

Parameters ​

nametypenotes
poolIdint
equipmentIdint
targetValuefloat7.0 to 8.0

Reply ​

Acknowledged only. The controller sends no reply.

Example ​

typescript
await omni.command("UISetCSADTargetValue", {
  poolId: 1,
  equipmentId: 1,
  targetValue: 0,
});

Request XML ​

xml
<?xml version="1.0" encoding="UTF-8"?>
<Request xmlns="http://nextgen.hayward.com/api">
  <Name>UISetCSADTargetValue</Name>
  <Parameters>
    <Parameter name="poolId" dataType="int">1</Parameter>
    <Parameter name="equipmentId" dataType="int">1</Parameter>
    <Parameter name="targetValue" dataType="float">0</Parameter>
  </Parameters>
</Request>

Response XML ​

None.

This software is not produced, endorsed, or supported by Hayward Industries, Inc. “Hayward” and “OmniLogic” are trademarks of their respective owners.