Skip to content

GetUIFreezeProtectOverrideInterval ​

Status VerifiedOpcode385TypeRead

Reads how long a freeze-protection override lasts.

Parameters ​

nametypenotes
poolIdint
equipmentIdint

Reply ​

Opcode1371

UIFreezeProtectOverrideIntervalRsp

nametypeunit
poolIdint
filterIdint
intervalint

Example ​

typescript
const reply = await omni.command("GetUIFreezeProtectOverrideInterval", {
  poolId: 1,
  equipmentId: 3,
});

Request XML ​

xml
<?xml version="1.0" encoding="UTF-8"?>
<Request xmlns="http://nextgen.hayward.com/api">
  <Name>GetUIFreezeProtectOverrideInterval</Name>
  <Parameters>
    <Parameter name="poolId" dataType="int">1</Parameter>
    <Parameter name="equipmentId" dataType="int">3</Parameter>
  </Parameters>
</Request>

Response XML ​

xml
<?xml version="1.0" encoding="UTF-8" ?>
<Response xmlns="http://nextgen.hayward.com/api">
  <Name>UIFreezeProtectOverrideIntervalRsp</Name>
  <Parameters>
    <Parameter name="PoolID" dataType="int">1</Parameter>
    <Parameter name="FilterID" dataType="int">3</Parameter>
    <Parameter name="Interval" dataType="int">7200</Parameter>
  </Parameters>
</Response>

This software is not produced, endorsed, or supported by Hayward Industries, Inc. “Hayward” and “OmniLogic” are trademarks of their respective owners.