SetStandAloneLightShow
Status VerifiedOpcode308TypeWrite
Runs a show on a ColorLogic light, optionally on a timer.
Parameters
| name | type | notes |
|---|---|---|
poolId | int | |
equipmentId | int | |
data | byte | the show number, from the light's show list |
field19 | byte | the speed on an OmniDirect light: 0 to 8 for 1/16x to 16x |
field1a | byte | the brightness on an OmniDirect light: 0 to 4 for 20 to 100 percent |
field1b | byte | 0 |
isCountDownTimer | byte | |
startTimeHours | byte | |
startTimeMinutes | byte | |
endTimeHours | byte | |
endTimeMinutes | byte | |
daysActive | byte | |
recurring | byte |
Reply
Acknowledged only. The controller sends no reply.
Example
typescript
import { timerParams } from "@rygine/omnilogic-local-sdk";
await omni.command("SetStandAloneLightShow", {
poolId: 1,
equipmentId: 1,
data: 0,
field19: 0,
field1a: 0,
field1b: 0,
...timerParams(),
});Request XML
xml
<?xml version="1.0" encoding="UTF-8"?>
<Request xmlns="http://nextgen.hayward.com/api">
<Name>SetStandAloneLightShow</Name>
<Parameters>
<Parameter name="poolId" dataType="int">1</Parameter>
<Parameter name="equipmentId" dataType="int">1</Parameter>
<Parameter name="data" dataType="byte">0</Parameter>
<Parameter name="field19" dataType="byte">0</Parameter>
<Parameter name="field1a" dataType="byte">0</Parameter>
<Parameter name="field1b" dataType="byte">0</Parameter>
<Parameter name="isCountDownTimer" dataType="byte">0</Parameter>
<Parameter name="startTimeHours" dataType="byte">0</Parameter>
<Parameter name="startTimeMinutes" dataType="byte">0</Parameter>
<Parameter name="endTimeHours" dataType="byte">0</Parameter>
<Parameter name="endTimeMinutes" dataType="byte">0</Parameter>
<Parameter name="daysActive" dataType="byte">0</Parameter>
<Parameter name="recurring" dataType="byte">0</Parameter>
</Parameters>
</Request>Response XML
None.