GetCHLORMeasurement
Status VerifiedOpcode163TypeRead
Reads the salt cell's electrical diagnostics: voltage, current, cell and board temperature, instant salt.
Parameters
| name | type | notes |
|---|---|---|
poolId | int | |
equipmentId | int |
Reply
Opcode1163GetCHLORMeasurementRsp
| name | type | unit |
|---|---|---|
poolId | int | |
chlorId | int | |
voltageHighByte | byte | |
voltageLowByte | byte | |
currentHighByte | byte | |
currentLowByte | byte | |
cellTempHighByte | byte | |
cellTempLowByte | byte | |
boardTempHighByte | byte | |
boardTempLowByte | byte | |
instantSaltLevelHighByte | byte | |
instantSaltLevelLowByte | byte | |
averageSaltLevelHighByte | byte | |
averageSaltLevelLowByte | byte |
Example
typescript
const reply = await omni.command("GetCHLORMeasurement", {
poolId: 1,
equipmentId: 6,
});Request XML
xml
<?xml version="1.0" encoding="UTF-8"?>
<Request xmlns="http://nextgen.hayward.com/api">
<Name>GetCHLORMeasurement</Name>
<Parameters>
<Parameter name="poolId" dataType="int">1</Parameter>
<Parameter name="equipmentId" dataType="int">6</Parameter>
</Parameters>
</Request>Response XML
Captured with the pump off and the cell idle.
xml
<Response xmlns="http://nextgen.hayward.com/api">
<Name>GetCHLORMeasurementRsp</Name>
<Parameters>
<Parameter name="PoolID" dataType="int">1</Parameter>
<Parameter name="ChlorID" dataType="int">7</Parameter>
<Parameter name="VoltageHighByte" dataType="byte">0</Parameter>
<Parameter name="VoltageLowByte" dataType="byte">202</Parameter>
<Parameter name="CurrentHighByte" dataType="byte">0</Parameter>
<Parameter name="CurrentLowByte" dataType="byte">0</Parameter>
<Parameter name="CellTempHighByte" dataType="byte">1</Parameter>
<Parameter name="CellTempLowByte" dataType="byte">172</Parameter>
<Parameter name="BoardTempHighByte" dataType="byte">0</Parameter>
<Parameter name="BoardTempLowByte" dataType="byte">221</Parameter>
<Parameter name="InstantSaltLevelHighByte" dataType="byte">11</Parameter>
<Parameter name="InstantSaltLevelLowByte" dataType="byte">176</Parameter>
<Parameter name="AverageSaltLevelHighByte" dataType="byte">12</Parameter>
<Parameter name="AverageSaltLevelLowByte" dataType="byte">145</Parameter>
</Parameters>
</Response>