SetUICSADORPAlarmLevel
Status UnverifiedOpcode283TypeWrite
Sets a Sense and Dispense module's two ORP alarm levels, 850 mV high and 350 mV low by default. A high ORP also stops chlorine generation.
Parameters
| name | type | notes |
|---|---|---|
poolId | int | |
equipmentId | int | |
data | int | |
field1c | int |
Reply
Acknowledged only. The controller sends no reply.
Example
typescript
await omni.command("SetUICSADORPAlarmLevel", {
poolId: 1,
equipmentId: 1,
data: 0,
field1c: 0,
});Request XML
xml
<?xml version="1.0" encoding="UTF-8"?>
<Request xmlns="http://nextgen.hayward.com/api">
<Name>SetUICSADORPAlarmLevel</Name>
<Parameters>
<Parameter name="poolId" dataType="int">1</Parameter>
<Parameter name="equipmentId" dataType="int">1</Parameter>
<Parameter name="data" dataType="int">0</Parameter>
<Parameter name="field1c" dataType="int">0</Parameter>
</Parameters>
</Request>Response XML
None.