GetHeaterLowSpeed
Status VerifiedOpcode359TypeRead
Reads the minimum pump speed a heat source requires.
Parameters
| name | type | notes |
|---|---|---|
poolId | int | |
equipmentId | int |
Reply
Opcode1359GetHeaterLowSpeedRsp
| name | type | unit |
|---|---|---|
poolId | int | |
heaterId | int | |
speed | int | percent |
Example
typescript
const reply = await omni.command("GetHeaterLowSpeed", {
poolId: 1,
equipmentId: 5,
});Request XML
xml
<?xml version="1.0" encoding="UTF-8"?>
<Request xmlns="http://nextgen.hayward.com/api">
<Name>GetHeaterLowSpeed</Name>
<Parameters>
<Parameter name="poolId" dataType="int">1</Parameter>
<Parameter name="equipmentId" dataType="int">5</Parameter>
</Parameters>
</Request>Response XML
xml
<?xml version="1.0" encoding="UTF-8" ?>
<Response xmlns="http://nextgen.hayward.com/api">
<Name>GetHeaterLowSpeedRsp</Name>
<Parameters>
<Parameter name="PoolID" dataType="int">1</Parameter>
<Parameter name="HeaterID" dataType="int">5</Parameter>
<Parameter name="Speed" dataType="int" unit="percent">60</Parameter>
</Parameters>
</Response>