SetUISystemStateCmd ​

Status UnverifiedOpcode268TypeWrite

Turns the system off or on, or puts the controller into or out of service mode, indefinitely or for a set time. The network switch intercepts it. The command still runs, but the controller does not reply to it as it would to a normal command.

Parameters ​

nametypenotes
dataint0 off, 1 on, 2 service, 3 config, 4 timed service
field1cinttimed service mode length in minutes. The panel offers 1 to 96 hours
isCountDownTimerint

Reply ​

Acknowledged only. The controller sends no reply.

Example ​

typescript
await omni.command("SetUISystemStateCmd", {
  data: 0,
  field1c: 0,
  isCountDownTimer: 0,
});

Request XML ​

xml
<?xml version="1.0" encoding="UTF-8"?>
<Request xmlns="http://nextgen.hayward.com/api">
  <Name>SetUISystemStateCmd</Name>
  <Parameters>
    <Parameter name="data" dataType="int">0</Parameter>
    <Parameter name="field1c" dataType="int">0</Parameter>
    <Parameter name="isCountDownTimer" dataType="int">0</Parameter>
  </Parameters>
</Request>

Response XML ​

None.