RunGroupCmd
Status VerifiedOpcode317TypeWrite
Runs a theme's saved snapshot with data 1, or turns off every device in it with data 0. With isCountDownTimer 1 and an end time, the controller turns it off when the time is up.
Parameters
| name | type | notes |
|---|---|---|
equipmentId | int | |
data | int | |
isCountDownTimer | byte | |
startTimeHours | byte | |
startTimeMinutes | byte | |
endTimeHours | byte | |
endTimeMinutes | byte | |
daysActive | byte | |
recurring | byte |
Reply
Acknowledged only. The controller sends no reply.
Example
typescript
import { timerParams } from "@rygine/omnilogic-local-sdk";
await omni.command("RunGroupCmd", {
equipmentId: 1,
data: 1,
...timerParams(),
});Request XML
xml
<?xml version="1.0" encoding="UTF-8"?>
<Request xmlns="http://nextgen.hayward.com/api">
<Name>RunGroupCmd</Name>
<Parameters>
<Parameter name="equipmentId" dataType="int">1</Parameter>
<Parameter name="data" dataType="int">1</Parameter>
<Parameter name="isCountDownTimer" dataType="byte">0</Parameter>
<Parameter name="startTimeHours" dataType="byte">0</Parameter>
<Parameter name="startTimeMinutes" dataType="byte">0</Parameter>
<Parameter name="endTimeHours" dataType="byte">0</Parameter>
<Parameter name="endTimeMinutes" dataType="byte">0</Parameter>
<Parameter name="daysActive" dataType="byte">0</Parameter>
<Parameter name="recurring" dataType="byte">0</Parameter>
</Parameters>
</Request>Response XML
None.