Skip to content

UISetCSADCalibrationValue ​

Status UnverifiedOpcode275TypeWrite

Sets a Sense and Dispense module's pH calibration adjustment: the tested pH minus the displayed pH.

Parameters ​

nametypenotes
poolIdint
equipmentIdint
calibrationValuefloattested minus displayed, such as -0.2

Reply ​

Acknowledged only. The controller sends no reply.

Example ​

typescript
await omni.command("UISetCSADCalibrationValue", {
  poolId: 1,
  equipmentId: 1,
  calibrationValue: 0,
});

Request XML ​

xml
<?xml version="1.0" encoding="UTF-8"?>
<Request xmlns="http://nextgen.hayward.com/api">
  <Name>UISetCSADCalibrationValue</Name>
  <Parameters>
    <Parameter name="poolId" dataType="int">1</Parameter>
    <Parameter name="equipmentId" dataType="int">1</Parameter>
    <Parameter name="calibrationValue" dataType="float">0</Parameter>
  </Parameters>
</Request>

Response XML ​

None.