Skip to content

SetCLSerialIdentifyStart ​

Status UnverifiedOpcode201TypeWrite

Makes a found networked ColorLogic light blink so it can be told apart by its serial number. Omni controllers do not offer this network-module feature.

Parameters ​

nametypenotes
poolIdint
equipmentIdint

Reply ​

Acknowledged only. The controller sends no reply.

Example ​

typescript
await omni.command("SetCLSerialIdentifyStart", {
  poolId: 1,
  equipmentId: 1,
});

Request XML ​

xml
<?xml version="1.0" encoding="UTF-8"?>
<Request xmlns="http://nextgen.hayward.com/api">
  <Name>SetCLSerialIdentifyStart</Name>
  <Parameters>
    <Parameter name="poolId" dataType="int">1</Parameter>
    <Parameter name="equipmentId" dataType="int">1</Parameter>
  </Parameters>
</Request>

Response XML ​

None.

This software is not produced, endorsed, or supported by Hayward Industries, Inc. “Hayward” and “OmniLogic” are trademarks of their respective owners.