GetHeaterEnable
Status VerifiedOpcode148TypeRead
Reads whether the heater is enabled.
Parameters
| name | type | notes |
|---|---|---|
poolId | int | |
equipmentId | int |
Reply
Opcode1148GetHeaterEnableRsp
| name | type | unit |
|---|---|---|
poolId | int | |
heaterId | int | |
enabled | bool |
Example
typescript
const reply = await omni.command("GetHeaterEnable", {
poolId: 1,
equipmentId: 4,
});Request XML
xml
<?xml version="1.0" encoding="UTF-8"?>
<Request xmlns="http://nextgen.hayward.com/api">
<Name>GetHeaterEnable</Name>
<Parameters>
<Parameter name="poolId" dataType="int">1</Parameter>
<Parameter name="equipmentId" dataType="int">4</Parameter>
</Parameters>
</Request>Response XML
xml
<?xml version="1.0" encoding="UTF-8" ?>
<Response xmlns="http://nextgen.hayward.com/api">
<Name>GetHeaterEnableRsp</Name>
<Parameters>
<Parameter name="PoolID" dataType="int">1</Parameter>
<Parameter name="HeaterID" dataType="int">4</Parameter>
<Parameter name="Enabled" dataType="bool">0</Parameter>
</Parameters>
</Response>