Skip to content

UISetCSADPHAlarmLevel ​

Status UnverifiedOpcode257TypeWrite

Sets a Sense and Dispense module's two pH alarm levels, 8.1 high and 6.9 low by default. Which parameter sets which is not known.

Parameters ​

nametypenotes
poolIdint
equipmentIdint
datafloat
field1cfloat

Reply ​

Acknowledged only. The controller sends no reply.

Example ​

typescript
await omni.command("UISetCSADPHAlarmLevel", {
  poolId: 1,
  equipmentId: 1,
  data: 0,
  field1c: 0,
});

Request XML ​

xml
<?xml version="1.0" encoding="UTF-8"?>
<Request xmlns="http://nextgen.hayward.com/api">
  <Name>UISetCSADPHAlarmLevel</Name>
  <Parameters>
    <Parameter name="poolId" dataType="int">1</Parameter>
    <Parameter name="equipmentId" dataType="int">1</Parameter>
    <Parameter name="data" dataType="float">0</Parameter>
    <Parameter name="field1c" dataType="float">0</Parameter>
  </Parameters>
</Request>

Response XML ​

None.