Skip to content

GetCHLORError ​

Status VerifiedOpcode159TypeRead

Reads the salt cell's error word.

Parameters ​

nametypenotes
poolIdint
equipmentIdint

Reply ​

Opcode1159

GetCHLORErrorRsp

nametypeunit
poolIdint
chlorIdint
errorHighBytebyte
errorLowBytebyte

Example ​

typescript
const reply = await omni.command("GetCHLORError", {
  poolId: 1,
  equipmentId: 6,
});

Request XML ​

xml
<?xml version="1.0" encoding="UTF-8"?>
<Request xmlns="http://nextgen.hayward.com/api">
  <Name>GetCHLORError</Name>
  <Parameters>
    <Parameter name="poolId" dataType="int">1</Parameter>
    <Parameter name="equipmentId" dataType="int">6</Parameter>
  </Parameters>
</Request>

Response XML ​

Captured with the pump off and the cell idle.

xml
<Response xmlns="http://nextgen.hayward.com/api">
  <Name>GetCHLORErrorRsp</Name>
  <Parameters>
    <Parameter name="PoolID" dataType="int">1</Parameter>
    <Parameter name="ChlorID" dataType="int">7</Parameter>
    <Parameter name="ErrorHighByte" dataType="byte">0</Parameter>
    <Parameter name="ErrorLowByte" dataType="byte">0</Parameter>
  </Parameters>
</Response>

This software is not produced, endorsed, or supported by Hayward Industries, Inc. “Hayward” and “OmniLogic” are trademarks of their respective owners.