Skip to content

GetUICHLOROperatingMode ​

Status VerifiedOpcode280TypeRead

Reads the chlorinator's operating mode: timed or ORP.

Parameters ​

nametypenotes
poolIdint
equipmentIdint

Reply ​

Opcode1280

GetUICHLOROperatingModeRsp

nametypeunit
poolIdint
chlorIdint
operatingModeint

Example ​

typescript
const reply = await omni.command("GetUICHLOROperatingMode", {
  poolId: 1,
  equipmentId: 6,
});

Request XML ​

xml
<?xml version="1.0" encoding="UTF-8"?>
<Request xmlns="http://nextgen.hayward.com/api">
  <Name>GetUICHLOROperatingMode</Name>
  <Parameters>
    <Parameter name="poolId" dataType="int">1</Parameter>
    <Parameter name="equipmentId" dataType="int">6</Parameter>
  </Parameters>
</Request>

Response XML ​

xml
<?xml version="1.0" encoding="UTF-8" ?>
<Response xmlns="http://nextgen.hayward.com/api">
  <Name>GetUICHLOROperatingModeRsp</Name>
  <Parameters>
    <Parameter name="PoolID" dataType="int">1</Parameter>
    <Parameter name="ChlorID" dataType="int">6</Parameter>
    <Parameter name="OperatingMode" dataType="int">1</Parameter>
  </Parameters>
</Response>

This software is not produced, endorsed, or supported by Hayward Industries, Inc. “Hayward” and “OmniLogic” are trademarks of their respective owners.